DAMAGE ASSESSMENT FOR BRICK BUILDINGS WITH RCC SLAB
This section provides a damage assessment by visual screening of damaged brick buildings with RCC slab and provides links to the measures required for rehabilitation of such buildings.

DAMAGE CATEGORY G-1
DAMAGES OBSERVED
-
Thin cracks in plaster
-
Falling of plaster in bits and pieces in limited parts
ACTION REQUIRED
-
Go to retrofitting

DAMAGE CATEGORY G-2
DAMAGES OBSERVED
-
Small cracks in walls through thickness
-
Falling of plaster in large bits over large areas
-
Damage to piers alongside of storey-height openings
ACTION REQUIRED
-
Go to retrofitting

DAMAGE CATEGORY G-3
DAMAGES OBSERVED
-
Large and deep cracks in walls
-
Widespread cracking of walls
-
Racking shear cracks
-
Large cracking and separation at corners of walls
ACTION REQUIRED
-
Go to retrofitting

DAMAGE CATEGORY G-4
DAMAGES OBSERVED
-
Gaps occur in walls
-
Some walls collapse partly or wholly
-
Separation at the corners remaining masonry badly shattered
-
Building appears in a dangerous state
ACTION REQUIRED
-
Unsafe building- stay away
-
Evacuate immediately
-
Consult technical expert

DAMAGE CATEGORY G-5
DAMAGES OBSERVED
-
Complete collapse of the building
ACTION REQUIRED
- Unsafe building and stay away
- Archive building material for temporary shelter and avoid pilfering.